IVRT 累计释放量报告

设备: Logan 918-12 (dry cell system)  |  V=12 mL  |  A=1.76625 cm²  |  含量=1500 μg/cm²

生成: 2026-08-16 11:51  |  未启用取样体积校正 (直接累加)

一、拟合汇总

吸收池释放速率 (μg/cm²/√h)截距R²终点累计 (μg/cm²)终点 %释放拟合方程
吸收池11045.1583-1171.66140.94754340.5508289.37%y = 1045.1583·√t + -1171.6614
吸收池21250.0772-1419.32990.94285216.1040347.74%y = 1250.0772·√t + -1419.3299
吸收池31156.0635-1323.77250.94014813.9966320.93%y = 1156.0635·√t + -1323.7725
吸收池4826.9613-920.02250.95023428.1362228.54%y = 826.9613·√t + -920.0225
吸收池5905.4925-1021.81000.94683747.6764249.85%y = 905.4925·√t + -1021.8100
吸收池61215.2012-1365.79690.94665054.6402336.98%y = 1215.2012·√t + -1365.7969
均值1066.4923-1203.73220.9457—295.57%y = 1066.4923·√t + -1203.7322
📐 计算公式(点击折叠/展开)

透过量:

Q(t) = C(t) × V

其中:C(t) = 药物浓度 (μg/mL);V = 吸收池体积 (12 mL)

累计透过量:

Cum(t) = Στ≤t Q(τ)

单位面积累计:

PerArea(t) = Cum(t) / A

其中:A = 有效扩散面积 (1.76625 cm²)

%释放:

%Released = PerArea(t) / 含量 × 100%

线性拟合(√时间):

PerArea = 释放速率 × √时间 + 截距

释放速率单位:μg/cm²/√h;截距反映初始突释或滞后

二、√时间 线性拟合

图1:各吸收池单位面积累计透过量 vs √时间,直线斜率 = 释放速率 (μg/cm²/√h)

三、各吸收池对比 (√时间)

图2:各吸收池累计释放曲线对比

四、%释放率对比

含量=1500.0 μg/cm²

图3:各吸收池 %释放率 vs √时间

辅助诊断图表

④ 释放速率对比 (含 95%% CI)

⑤ 残差分析 — 线性诊断

⑥ 汇总仪表盘

六、释放仿真动图 GIF

释放仿真动图
Logan 918-12 细胞示意 — 液面恒定,粒子逐步点亮表示累计释放增多

七、明细数据 单位面积累计 (μg/cm²) / %%释放

时间 (h)吸收池1 累计 (μg/cm²)吸收池1 %释放吸收池2 累计 (μg/cm²)吸收池2 %释放吸收池3 累计 (μg/cm²)吸收池3 %释放吸收池4 累计 (μg/cm²)吸收池4 %释放吸收池5 累计 (μg/cm²)吸收池5 %释放吸收池6 累计 (μg/cm²)吸收池6 %释放
0.50034.67462.3145.31753.0234.83482.3224.76501.6530.78522.0540.40092.69
1.000104.95047.00119.32247.95109.72617.3283.74995.5882.00825.47116.30777.75
2.000232.870815.52270.970718.06248.455316.56195.560113.04192.046212.80279.122318.61
4.000529.532635.30604.150240.28533.347835.56424.499728.30437.365229.16612.772440.85
6.000956.131763.741110.594974.041003.088366.87773.174651.54830.467555.361107.662173.84
8.0001568.8422104.591830.7881122.051650.1276110.011259.325783.961344.183489.611800.4429120.03
12.0002468.7476164.582902.4596193.502706.6754180.451966.3198131.092150.1266143.342862.2674190.82
24.0004340.5508289.375216.1040347.744813.9966320.933428.1362228.543747.6764249.855054.6402336.98
📐 公式参考

累计透过量 = Σ[浓度(μg/mL) × 体积(mL)]

单位面积累计 = 累计透过量 / 面积(cm²)

%%释放 = 单位面积累计 / 成品含量 × 100%%

报告结束 | 生成时间: 2026-08-16 11:51 | IVRT Logan 918-12 自动生成